Views:

Question 
Can I output details regarding heat flux from my MIKE FM simulation? 

Answer 
Yes.  This is possible.

Solution
It is possible to output heat flux data by manually modifying the parameter storage = 1 in the [HEAT_EXCHANGE] section in the input file (the default value is 0) - see  example in Fig. 1


Fig. 1 - Modification of the parameter storage = 1 in the [HEAT_EXCHANGE] section in the input file (the default value is 0)

This will enforce the output of the following 6 additional items in all output files of the type '2D (horizontal)':

- Sensible heat flux 
- Latent heat flux
- Net short wave radiation 
- Net long wave radiation
- Ground heat flux
- Total heat flux (from all processes)

 

FURTHER INFORMATION & USEFUL LINKS 

Manuals and User Guides 
User Guide. MIKE 21 Flow Model FM. Hydrodynamic Module

 

Related Products: MIKE 21/3